HICOM 100E PDF

The Hicom E PBX system, the new family of systems with professional phone system for small and medium enterprises. The system supports ISDN and. responsibility for errors or omissions contained herein. Configuration Note – Ver C (03/01). Siemens Hicom E/E. & Office. Enhanced DTMF In-Band. Hicom E Hicom Hicom Hicom E Hicom Hicom Hicom Hicom , Hicom , Hicom , Hicom E. Hicom E OfficePoint.

Author: Negal Melkree
Country: Lesotho
Language: English (Spanish)
Genre: Marketing
Published (Last): 21 June 2010
Pages: 246
PDF File Size: 20.6 Mb
ePub File Size: 12.99 Mb
ISBN: 687-7-67468-506-9
Downloads: 31911
Price: Free* [*Free Regsitration Required]
Uploader: Tausho

Issued by All rights reserved. Information and Communication Networks Subject to availability. Siemens Aktiengesellschaft Reference No.: Pin assignment of the printer adapter Figure Equipping sequence for the expansion box Codes for accessing services Overview of item code numbers These symbols are not usually used in the manual.

During a thunderstorm, you should not connect or remove telephone lines and PCB boards. Expect to encounter leakage hicok from the telecommunication network.

Ensure that, whenever work is carried out on an open installation, the installation is never left unsupervised. Never try to lift heavy objects without assistance. In case of laser radiation: Install cables in such a way that they do not pose an accident risk i. Do not allow readily flammable materials to be stored near the installation or in the installation room.

Ensure good lighting at the workplace. Untidiness at the workplace involves the risk of injuries.

What type of injuries? Report all electrical shocks, no matter how small. The basic configuration of each system can be ex- panded and supplemented in different ways.

SIB serial interface board optional V. Plug in and secure screw Plug in and secure screw Plug in Function expansions Figure Hicom structural concept Slots 1 to 4 for system extensions: Hicom basic configuration Hicom with max.

If condensation forms, allow the appliance to dry before operation. It is essential to ensure that condensation cannot form while the appliance is in op- eration. Range m using cable with 0. As of SW 2. ISDN and analogue trunk connections is not possible. Hicom has two slots that are used for line modules analogue trunk, S. A combination of ISDN and analogue trunk 100e is possible. Figure Equipping sequence for extension and trunk modules The structure of the extension number plans is described in more detail in Chapter 5, Installation of the Service Manual see Section 5.

The above table only shows the possible slots. It does not illustrate the hivom configuration possible or authorization-related hiccom. Only SLAS8 modules can be inserted in slots 1 and 2.

Power supplies for Siemens Hicom 100E (108/112/118)

SLU modules must not be inserted in slot 1. Overview of modules Add-on modules for system expansions For Hicommodule cutover is dependent on the system code, i. The channel for call charge recognition is looped into the trunk and then routed to the TLA. The call- er will incur call charges from the start of the announcement. Contact assignment of the fax recognition and DDI module Caution Normally, W1 and W2 are always jumpered and the jumper must be inserted before initial operation.

  GREGORIO DI TOURS STORIA DEI FRANCHI PDF

Do not remove jumpers unless expressly instructed to do so. Printer Modem Figure Pin assignment of the V. National regulations must be observed. Generally speaking, the systems are not suit- able for a cable that exits the building. Before commencing work on the system or installing expansions, always pull the power plug, disconnect screw connections and pull the PSU or UPS, as otherwise the modules may be damaged.

PC board connectors for the terminal blocks. The terminal blocks required for wiring are supplied with the respective modules. Call keys virtual line keys Line seizure, automatic Via trunk group and overflow trunk group Dial pause With analogue trunk programmable Project code Max.

From 4 entrance telephones, also follows call diversion as of SW 2. Resetting a call Although a call is signalled, the called extension can seize another line without answering the first call.

The first call is then signalled as a camp-on call. Internal conference with additional external ext. When using an existing DDI number for specific seizure, the procedure must first be called up by entering the appropriate code. The DDI number is then dialled before selecting the required call number. This feature can be used from the local attendant console not network-wide or from any other attendant con- sole, an attendant console group or from the night station. They may consist of several components depending on the version and on the requirements.

UPS only Figure Connecting the UPS battery cable Danger Do not insert the power cable in the mains socket until all installation and connection work has been completed. If a UPS is fitted, always deactivate battery mode before pulling the mains plug. If a changed equipping scheme is detected during startup: MSNs of the terminals irrespective of the equipping scheme. The following scheme applies to the allocation of the default MSNs of the 16 possible S ports used if no MSN is assigned to the terminal: Plug the other end into the Hicom The other S interfaces 2, 3 and 4 are assigned the extension numbers of the next three extensions in ascending order as their MSNs.

Pin assignments Mini-Western sockets: In the case of mixed equipping, a distinction must be made between the routes. Call forwarding in the exchange is only supported at extension 11 in the case of PMP. Up to 4 entrance telephones can be connected. The system activates analogue ports only after seizure.

  ENFILADO DENTARIO PDF

See Programming guide, Section Plug the power cable into the re-connected power supply. Re-initialise the system not necessary, if only previously unoccupied free slots are used. Supplement customer data if necessary, see Section 6. A special password must be entered in order to modify an option that is connected and recognized.

Siemens Hicom E :: Briescom

After entering this password and resetting the system, the modules currently connected are recognized by the system. This ensures that the extension number plan of the basic box and the expansion box is uniform. Entry 5 one cell for defining the call diversion time for cells 1—4.

Entry 6 one cell for forwarding handling common ringer. Entry 7 one cell for connection type of common ringer or secondary telephone. Call management CM 6. Intercept criteria No answer, busy, invalid, incomplete, recall Call allocation continues in block 2 call signalling. Call type Functions are: With the default setting, the- se ext. The call forwarding timeout for this list should be set to 15 rings so that calls are not forwarded when the intercept console is functioning properly.

Collision with one of the route codes Assign codes route code entered Collision with Collision with one of the internal ex- int. Digit repetition was deactivated when digit repetition attempt was made to assign additio- nal route codes Table Error messages for network settings Error messages must be acknowledged before you proceed with programming.

With these settings, the three systems work together as a whole. Regardless of where you are within the company, the extension and telephone numbers are always the same. Examples do not apply in the case of closed numbering.

Once the system has re-booted, perform system Nationalisation Section 6.

If an error message appears, abort the load process and start again from point 7 of the upgrade instructions. A new file is automatically created, “konvert. This contains the customer programming on the SW 2. Initial operation Converting from SW 2. Simply follow the user prompts; the system will always inform you of available and unavailable error messages options and will recommend corrective measures using expert mode branch address to collision entry found.

Barred numbers list 5, 10 items Barred numbers list 6, 10 items Total active exts. Internal calls, select ext. Classes of service Night service, enter ext. Disable time, select sensor 1—4 and enter 0— Sensor name, select sensor 1—4, enter alphanumeric 1000e max.

Interpreted digits LCR type 3 only max.