ASTM D1822 PDF

This standard is issued under the fixed designation D ; the number 1 This test method is under the jurisdiction of ASTM Committee D on Plastics. ASTM D Standard Test Method for Tensile-Impact Energy to Break Plastics and Electrical Insulating Materials. standard by ASTM. This test is used for materials that are either too flexible or too thin to be tested with ASTM D Strain rate is somewhere between that of ASTM D and.

Author: Gorr Arashitilar
Country: Pakistan
Language: English (Spanish)
Genre: Career
Published (Last): 5 April 2017
Pages: 296
PDF File Size: 6.49 Mb
ePub File Size: 15.17 Mb
ISBN: 705-8-84428-680-9
Downloads: 21465
Price: Free* [*Free Regsitration Required]
Uploader: Arashikree

D1822 Version s – view previous versions of standard. Work Item s – proposed revisions of this standard. To compensate for the minor differences in cross-sectional area of the specimens, the energy to break is normalized to units of kilojoules per square metre or foot-pounds-force per square inch of minimum cross-sectional area.

An alternative approach to normalizing the impact energy that compensates for these minor differences and still retains the test unit as joules foot-pounds is shown in Section For a perfectly elastic material, the impact energy is usually reported per unit volume of material undergoing deformation. However, since much of the energy to break the plastic materials for which this test method is written is dissipated in drawing of only a portion of the test region, such normalization on a volume basis is not feasible.

  INDICE TOCOLITICO PDF

r1822

ASTM D1822 Tensile Impact Energy of Plastic | Test Machines & Equipment

In c1822 to observe the effect of elongation or rate of extension, or both, upon the result, the test method permits two specimen geometries. Results obtained with different capacity machines generally are not comparable.

In general, the Type S specimen with its greater occurrence of brittle fracture gives greater reproducibility, but less differentiation among materials.

Some materials exhibit a transition d18222 different failure mechanisms. If so, the elongation will be critically dependent on the rate of extension encountered in the test. The impact energy values for a group of such specimens will have an abnormally large dispersion. With such materials, determining the type of failure, ductile or brittle, by examining the broken pieces is difficult, if not impossible.

It is helpful to sort a set of specimens into two groups by observing the broken pieces to ascertain whether or not there was necking during the test. Qualitatively, the strain rates encountered here are intermediate between the high rate of the Izod test of Test Methods D and the low rate of usual tension testing in accordance with Test Method D Therefore, given the same specimen geometry, it is possible that one material will produce tensile-impact energies for fracture due to a large force associated with a small elongation, and another material will produce the same energy for fracture result due to a small force associated with a large elongation.

It shall not be assumed that this test method will correlate with other tests or end uses unless such a correlation has been established by experiment. Comparisons between molded and machined specimens must not be made without first establishing quantitatively the differences inherent between the two methods of preparation.

  LEY DE PENSIONES ALIMENTARIAS COSTA RICA 7654 PDF

Therefore, it is advisable to refer to that material specification before using this test method. Rigid materials are suitable for testing by this method as well as specimens that are too flexible or thin to be tested in accordance with other impact test methods.

The values given in parentheses are for information only. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of d122 standard.

Tensile Impact ASTM D

Note 2 — Friction losses are largely eliminated by careful design and proper operation of the testing machine. Note 1 — This test method and ISO address the same subject matter, but differ in technical content. Link to Active This link will always route to the current Aetm version of the standard.